ALr 48 - Manual shutdown (long touch disable)
In this situation, the cooler has been intentionally placed into a manual shutdown state by an on-site user or technician using the display keypad shortcut. ( FW 4028.2 onwards).
When this feature is enabled, holding both the Left and Right keypad buttons simultaneously for 2 seconds:
-
Turns off all controller outputs (compressor, fans, lights)
-
Illuminates the Alarm LED
-
Displays OFF on the screen
-
Logs ALr 48 to the event history.
Re-enabling depends on the method:
-
Keypad: press and hold both the Left and Right buttons simultaneously for at least 2 seconds, until the display reverts to the standard temperature readout and normal refrigeration resumes.
-
Power cycle: disconnect and reconnect mains power to clear the manual shutdown state and resume normal operation.
-
Parameter configuration: if accidental shutdowns occur frequently, disable the Long Touch parameter in the controller’s parameter profile using the AoFrio Field app or Cradle app.