Normal Mode parameters for the SCS Controller
A summary of 'Normal Mode' parameters for the SCS Controller including the digital display codes, increments, logging (to the Cloud) and default settings.
-
When running in Normal Mode, the SCS controller primarily operates to maintain the Set Point Temperature.
-
Find out how to Edit parameter files using Field app
Temperature
| Parameter name | Digital display | Increments & units | Range | Default |
| Operational Set Point | SP | 0.1 °C | -10.0 to 15.0 °C | 3.5 °C |
| Operational Differential | dIF | 0.1 °C | 0.1 to 10.0 °C | 3.0 °C |
| Maximum User Set Point | SPt | 0.1 °C | -10.0 to 15.0 °C | 6.0 °C |
| Minimum User Set Point | SP- | 0.1 °C | -10.0 to 15.0 °C | 2.0 °C |
Evaporator Fan
| Parameter name | Digital display | Increments & units | Range | Default |
| Evaporator Fan On Time - Normal Mode |
Fot | 1 min | 0 to 30 mins | 2 mins |
| Evaporator Fan Off Time - Normal Mode |
FoF | 1 min | 0 to 30 mins | 2 mins |
Time
| Parameter name | Digital display | Increments & units | Range | Default |
| Inactivity Wait Time - Normal Mode |
Ytn | 0.5 hours | 0.5 to 24 hours or InFinite |
2 hours |
Alarms
| Parameter name | Digital display | Increments & units | Range | Default |
| High Temperature Alarm Setpoint* | htA | 0.1 °C | -10.0 to 15.0 | dISabled |
| Low Temperature Alarm Setpoint* | LtA | 0.1 °C | -5.0 to 20.0 | dISabled |
Operational settings
| Parameter name | Digital display | Increments & units | Range | Default |
| Operational Setpoint | SP | 0.1 °C | -35.0 to 20.0 | 3.5 °C |
| Operational Differential | dIF | 0.1 °C | 0.1 to 10.0 | 3.0 °C |
Lighting & Display
| Parameter name | Digital display | Increments & units | Range | Default |
| Display value during Normal Mode** | - | dlS | intergers | 0 to 3 |
| Light State Normal Mode - Channel A | LnA | 1 % | 0 to 100 | 100 % |
| Light State Normal Mode - Channel B | LnB | 1 % | 0 to 100 | 100 % |
| Light State Normal Mode - Channel C | LnC | 1 % | 0 to 100 | 100 % |
| Light State Normal Mode - Channel D | LnD | 1 % | 0 to 100 | 100 % |
| Light State Normal Mode - Channel E | LnE | integers | 0 to 1 | 1 |
Temperature Alarm Setpoint
| Parameter name | Digital display | Increments & units | Range | Default |
| High Temperature Alarm Setpoint | htA | 0.1 °C | -35.0 to 25.0 or disabled | disabled |
| Low Temperature Alarm Setpoint | LtA | 0.1 °C | -40.0 to 20.0 or disabled | disabled |
| Temperature Out-Of-Spec Alarm Delay | - | 1 min | 1 to 240 | 30 mins |
Logging
The Logging Parameters define how data is logged and sent to the Cloud.
| Parameter name | Digital display | Increments & units | Range | Default |
| Logging interval | LGt | mins | 30 to 1440 | 30 |
*Options 1 & 2 are not functioning
** Not yet implemented